BestGrout CE775
No shrinkage Flowable Grout, Modified Polymer-Cement based.
Advantages
:
-
Very high and consistent mechanical properties.
-
Excellent workability, and flow ability.
-
Good self-leveling, and compacting characteristics.
-
Non-shrinking, expanding mortar.
-
Very easy application.
-
Non-toxic.
-
Chloride-free, non-corrosion to reinforced steel bars.
Download documents
EN VN
-
BestGrout CE775 is a high compressive strength, non-shrinkage, flowable, cement-based compound, supplied in premixed powder, ready to use.
-
It consists special Portland cement, selected quartz sand and special chemicals.
BestGrout CE775 is recommended for use such as:
- Anchoring bolts, heavy machinery assembling, pointing.
- Mounting plates of construction posts, and keys of bridges.
- Sealing joints of concrete pipes.
- Filling large slots, big concrete honeycombs...
- Patching eroded concrete...
- Special precast concrete members.
- Very high and consistent mechanical properties.
- Excellent workability, and flow ability.
- Good self-leveling, and compacting characteristics.
- Non-shrinking, expanding mortar.
- Very easy application.
- Non-toxic.
-
Chloride-free, non-corrosion to reinforced steel bars.
SPECIFICATION
Color/Supply form:
|
Cement grey color/Dry powder.
|
Bulk density:
|
1.6 kg/ Liter |
Specific density:
|
Dry powder: 2.85 kg/liter
Grout: 2.20 kg/liter
|
Consumption:
|
1.92 kg/liter. Need 77 bags for 1m3 mortar.. |
Application temperature:
|
Minimum ambient temperature to apply: 15oC
|
Waterproof resistance:
|
Reinforce the waterproof resistance for structures.
|
Mechanical strength:
|
Increase the mechanical impact resistance.
|
Application time:
|
Within 15 minutes after mixing.
|
Package:
|
25kg/bag. |
Preserve:
|
At a cool and dry place. |
Shelf life:
|
12 months from date of manufacture.
|
Mechanical properties:
Properties
|
Value
|
Standard
|
Water content (%)
|
11 ± 1 |
|
Flowing (mm)
|
230 ÷ 320 |
ASTM C230 |
Expansion at 1;3;14;28 days (%) |
0 ÷ 0.3
|
ASTM C940 |
Compressive strength (MPa)
1 day * 3 day * 7 day * 28 day ** |
≥ 27 ≥ 45 ≥60 ≥75 |
ASTM C942 |
* : The results for reference.
** :Final result.
Surface preparation:
- The surface must be clean, solid, and free from grease or impurities, and must be treated as leaking before (if any). The water absorption surface must be saturated to avoid water loss locally and reduce the flow of materials in the application process.
Mixing:
-
BestGrout CE775 powder is added slowly to the mixing water to achieve flexibility (viscosity) as required. However, typically, the optimum mixing water is 11% compared to the weight of powder (2.75 liters of water per 25 kg bag of BestGrout CE775). Use a paddle mixer with a speed of 500-600 revolutions /minute to mix the compound until achieving the homogeneous as required (about 3 minutes).
Application:
- After mixing, use an iron trowel to stir lightly for a few seconds to release air bubbles. Then, pour the compound immediately into the prepared framework continuously to maintain the pressure necessary for filling the material layer to avoid air entrapment in the structure.
- Note: The framework must be checked and guaranteed not to leak water during application and before the compound gets cured. Do not use materials that application time over.
Important notes:
-
The product is applied to the minimum clearance of structure is 8 mm
-
Curing procedures should be ensured strictly as products originating from other cement. When applying to large structures with a thickness greater than 60 mm, to save materials and reduce the heat of hydrolysis, hydration should add large aggregates carefully selected ( such as gravel, small stone 1x1)
-
Which is the quantity from 50÷100% and the mixing water is not over 12% to the initial weight of BestGrout CE775. Should be tested before application.
Cleaning:
-
Clean tools and equipment with water before the mixed grout hardens.
Safety:
- BestGrout CE775 is alkaline like normal cement and can cause skin irritations to persons with sensitive skin. Wear gloves and masks while handling the product. In case of accidental eye contact, wash with fresh water and seek medical advice immediately.